Perc h710 hard drive compatibility It should recognize hard drives and give you an option to import RAID configuration at first boot. Oct 19, 2012 · Hello jtubb It sounds like you recently installed a PERC H710 and the system was originally configured to use the integrated S110. Jan 2, 2025 · Can older Perc cards be used in newer servers? In a case example, a newer server a company got doesn’t have a decent card in their server, no cache, no raid5+ support etc. Then I should b Mar 6, 2012 · PERC H710 Adapter firmware release 21. 00. 7-7 upgrade through vSphere rather than booting the ISO for 7 and installing over 6. 1, 8, or 7. I searched the Dell support site and did not find a relevant page. 64 running for Dell PERC H310/H710/H710P/H810 Controllersfor the following Windows operating systems: Windows 2008 R2 64 Bit Oct 30, 2025 · This article lists the PowerEdge RAID Controllers (PERC) by series family (generation) for Dell systems. To start, I wasn't worried about the PERC or the ConnectX being supported as in 7, I had those passed through to a TrueNAS VM. - DELL PowerEdge R820 - CPU : 4 x 2. Does anyone know what kind of Drives I can use as I can not find any specifications? Apr 16, 2021 · Hi all, I have an older T420 that's new to me. The vSphere 7 image and the Dell customized image does not discover local storage on the PERC H310 Mini controller. You can deploy the PERC H730P in hard-drive-based server environments for significant performance gains. It then promptly failed to actually install, but because VMware apparently wants you to install the 6. 5" Drive bays and a PERC H700 RAID controller. Nov 2, 2022 · I have a Dell R720 server running Truenas Scale with a Dell perc H710 mini that is flashed to IT mode (reporting as LSI SAS9207-8i firmware 20. The double module channel provides high-speed connectivity. Please note: The controller does not allow import of configurations that results in more than 64 virtual disks for an Enterprise-Level PERC Controller and 32 virtual disks for an entry-level PERC Controller. So all I did was create a virtual disk in the rear controller with both of those drives in and manually initialise it This is appears to be due to the Perc H710p not supporting 4Kn drives even though the stores advertised them as compatible 🙄 So I'm now on the hunt for more 1. 5" model is compatible with SATA and NL-SAS drives up to 4TB. May 6, 2017 · I ordered 4x Intel SSD DC P3520 2. I have followed the guide created by @fohdeesha and I have done all the steps, including disabling the Virtualisation in the Bios For reference, it has 2x e5-2680 v2 CPUs, perc h710 mini flashed to IT mode, an Intel 10gbe, and an ConnectX-3 nic set to Ethernet Only (40gbe). 8 TB SAS HDD 10K drives. The previous generations do not. If you are implementing hybrid server platforms based on solid-state storage, these next-generation PERCs exploit the potential of solid Dell Express Flash drives use PCIe lanes to connect directly to the processor and chipset and are easily accessible through a hot-plug drive bay. If you experience non-detected hard disk drives, the issue is most likely causing by a driver of the hard disk controller, as Dell May 23, 2020 · The H710/H730 Mini have 512MB DDR3, with a battery backup to protect that RAM from power failures. . 0Gb/s 3. RAID 5 should not be used with modern hard drives because rebuild times are long enough that a second drive could fail causing the entire array to be lost. 60Ghz E5-4650L Xeon Eight Core - RAM : 12 x 16GB PC3L-10600, [192GB Total] - HDD : 8 x 960GB SSD SATA 2. Physical disk power management (Dimmer SwitchTM) technology provides Feb 21, 2025 · This article provides information about in-box and out-of-box drivers for Dell EMC PowerEdge servers and Windows Server 2022. The remaining eight stripes are allocated in the PERC H710P: The PERC H710P is the same as the H710 with increased non-volatile flash write cache to 1GB. Apr 30, 2019 · I am trying to upgrade a T320 from 2TB SATA drives in a RAID10 array to 4TB SAS drives (still in a RAID10 array) one at a time. According to the product brief, the PERC H730 is compatible with SAS and SATA disks. It should be able to interact with any Manage data overload Keep pace with the explosion of data in the virtual age with the flexible, powerful I/O and storage capabilities of the R720. Download and install the latest drivers, firmware and software for Windows devices. May 17, 2018 · Windows PERCCLI Utility For All PERC Controllers This file was automatically installed as part of a recent update. My question are 512e drives compatible with the Perc H710p mini? I don't want a repeat of purchasing incompatible drives again. 5". Mixed SAS/SATA drives cannot be combined in a single common virtual disk or RAID set, but you can create separate VDs with various types (RAID1 on SAS, and a separate RAID5 on SATA). Upgrade to PERC H710 Yep, so I bit the bullet and invested in a H710 RAID adapter. We are looking to build a configuration that has at least 900GB (pref 1TB) of SAS storage (10K or ab Mar 5, 2024 · This release updates Windows 2022 Server driver to 7. 07. 2TB disks I ha Hi, I have a Dell R620 with Perc H710 Mini with SAS/SATA 6Gbps interface and HDDs which I'm looking to upgrade to SATA SSD. 0 for PERC H740P, H840, H745P MX, H745 Adapter, H745 Front, H345 Adapter, H345 Front, H755 Front, H755N I have a Dell server running CentOS 6 using PERC H710 Raid Controller card with Raid 5 setup and I want to monitor the hard disk failure/working status behind the Raid Controller. in tecnical guide says very smaller capaticities on page 26 ESG-PowerEdge-R720 sponding hard drives 0, 1, 2, and 3. May 1, 2019 · I have a Precision workstation T7600 that currently has a PERC H710 controller with four SATA hard drives connected. Jan 24, 2023 · I have a PowerEdge R710 with a 6 x 3. Aside from that, you can go crazy with non certified dell hardware. 6in) x 64. All of these options can be selected in a tower or rack configuration at the time of purchase. Feb 24, 2023 · 6Gbps SAS Hot Plug Enterprise Hard Drive/ Dell PERC H710 RAID Controller (Raid 0,1,5) Support / 1 PCIe Slots/ 4X1Gb Gigabit Network Lan Ports /Hot Plug|Hot Swap dual Dell 750W Power supply/ universal rail kits Note: this model is 40% more expensive than the 1st one, and this one is definitely overkill for my requirement. Looking through the Dell spec sheet, the H710 is based on the LSI SAS2208 chipset. Source: Documentation (below), and personal experience in Dell Storage Support. Dell PowerEdge RAID Controller (PERC) H310, H710, H710P, and H810 User’s Guide Regulatory Model: UCSA-801, UCSB-800, UCSM-800, Mar 22, 2020 · Hello, I have a R720 currently with a PERC H710P Mini and upgraded my data HHDs to 4 Seagate Exos 6TB 4kn SAS drives, and exactly those are the problem. Where Oct 31, 2022 · If I'm understanding correctly, you're asking about compatibility between the controller, and any possible hard disk drives. Aug 12, 2025 · In addition, you can view the foreign configuration from the "Foreign View" tab without importing the configuration. Jul 25, 2017 · • Supports Dell-qualified serial-attached SCSI (SAS) hard drives, SATA hard drives, and solid-state drives (SSDs). The R720 supports up to sixteen internal hard drives to increase your capacity, while optional hot-plug, front-access Express Flash PCIe solid-state drives (up to four) enable performance-enhancing, in-box storage tiering. The PowerEdge RAID Controller (PERC) H710, with eight internal ports, delivers two PowerPC processor cores and a 72-bit DDR3 interface that drives 512 MB cache memory. 5"HDD. The update contains changes to maintain overall system health. 0TB SSD drives for our new Dell PowerEdge R720, but when I put the drives in and booted to the PERC RAID configuration page, it is not seeing them. I have a 1TB p Mar 3, 2015 · The hard drives will be Seagate STBD6000100 6TB 128MB Cache SATA 6. 64 and a chassis with up to 8HD (can provide service tag if helpful). CacheCade uses Dell PERC storage controllers to accelerate performance over hard drives or traditional solid-state drives. I will only have 2 of them at the time I purchase the H710 card so thats really why I needed a firm yes or no that it would work or not into the future when i all 6TB’s to the remaining 4 caddys. 721. Does anyone have a confirmed list of supported SATA and Mar 8, 2022 · I have a PowerEdge R720 server with PERC H710 Mini controller and i would like to replace HDD with SSD without losing any data. Up to 16 internal hard drives and integrated PCI Express® (PCIe) 3. The card is available in Adapter (low profile and full height), Mini Monolithic, and Mini Blade form factors for internal storage and tape devices. I would like to know what SSD is compatible for sure with R620 and Perc H710. Get drivers and downloads for your PowerEdge RAID Controller H710P. Apr 21, 2021 · The RAID controller is PERC H710 Mini running firmware version 21. I'm not concerned about Consumer grade SSD vs Enterprise SSD (Have read about it, and I'm using for homelab so my IOPS will undoubtedly be low). This file was automatically installed as part of a recent update. Feb 17, 2023 · As the title describes, I'm having trouble booting from the hard drives after I have (successfully) flashed the PERC H710 Mini controller in my new Dell R720 Server. I've read about flashing the raid controller into IT mode and things but i've also read that this can easily brick your raid controller. Security Key Implementation The Dell PowerEdge RAID Controller (PERC) H710, H710P, and H810 cards support Self-Encrypting Disks (SED) for protection of data against loss or theft of SEDs. The H710 RAID controller is special in that you must use the RAID functionality to get the drives advertised to the OS …. You can deploy the PERC H730 in hard drive-based server environments for significant performance gains. Apr 8, 2020 · I have a lot of Dell R620s with varying PERC controllers. (firmware version 20. Because of this, it seems like more Gen11 machines shipped with the SATA-II PERC6 that wasn't locked-down, instead of the H710 that was originally locked down. Offers Non-RAID support for direct access to disk drives (PERC H310 only). You can deploy the PERC H710 in hard-drive-based server environment for significant performance gains. Since the H700 has confirmed large-drive support (>2TB), there's a strong likelihood that they will work. R420 has three chassis to support up to three different drive-bay options. Jun 29, 2017 · 4k/512e Drive support on Perc H710 & 810 Good evening, More of a question regarding the future of Enterprise RAID controllers. 1. From my research online it appears that the PERC H710 mini were originally released with nerfed firmware that caused incompatibility errors/warnings with non-Dell drives. 5-inch hard drives or up to 32 2. Stripe E, however, appears on a segment of drive 0 in a different location than stripe A; stripes F through H app ar accordingly on drives 1, 2 and 3. 5" Crucial C300 60GB Old consumer HDD - 2. They are recognized as 698Gb and state 'bloc Keep pace with the explosion of data in the virtual age with the flexible I/O and storage capabilities of the R720 and R720xd. The current T420 has: PERC H710 Adapter RAID Controller, 512MB NV Cache 6 x 300GB, SAS 6Gbps, 2. Thanks Mar 21, 2016 · The first firmware update added support for >2TB drives on the H700 controller. The configuration I want to become is: PE The Dell PowerEdge Expandable RAID Controller (PERC) 9 Series of cards consist of the H330, H730, H730P, H730P MX, and H830 cards. 5" 6GB/s (Samsung PM853T) - RAID : PERC H710 (I ordered a H310 since H710 doesn't support HBA or Sep 21, 2022 · Windows Server 2022 has built-in drivers for Poweredge Gen10 RAID controllers. But as long as the drives use the 512e sector size format I think you can use various large capacity hard drives. So that detail aside, it does look as though the H710 controller is compatible. Only the PERC H310 controller allows configuration of disk drives as Non-RAID. 2-0001 I would like to know if the RAID controller supports SSD and that the necessary TRIM and Wear Levelling will be handled by the RAID controller. Looking to speed up system, and maximize capacity with SSD, preferably hardware encryp Mar 26, 2012 · Your post had me curious. The remaining eight stripes are allocated in the May 1, 2022 · Dell poweredge t320 with perc h710 card hard rrive compatibility Hi im in the process of replacing the drives of my dell t320 server running windows server 2012 essentials And thinking of buying 4 drives from seagate model SEAGATE ST8000NM001A 8TB 7200 RPM 256MB SAS 3. Dell EMC PowerEdge systems — VMware vCenter Server compatibility matrix VMware vCenter Server is supported on a limited set of Microsoft Windows operating systems. But first, exactly what is a 4Kn hard drive? Hard drives are divided into partitions or sectors, which is the minimum data storage unit in a drive. 7. I have four 14TB drives in a RAID5 set up on the 710. 4mm (2. I'm about to populate it with drives from scratch. The new server will be a PowerEdge The PERC H330 entry-level controller card ofers a straightforward solution that includes essential RAID levels and support for non-RAID (pass-through) configuration options. Features of PERC H330 adapter card PERC Aug 16, 2024 · All SSDs ZFS Setup Hi guys, Need help to get best performance for my server. reaming digital media environments. Aug 15, 2017 · Adding Hard Drive to Perc H710 We have a Dell T320 tower server with a Perc H710 and 3 - 2Tb SAS hard drives configured in RAID5. I have not seen any drives larger than that tested, but I think most current generation high-volume drives are commonly 4k drives, which means they are less likely to work. Jan 31, 2018 · Hello, we are in the process of looking to upgrade the hard drive to a Dell Precision T7600 (circa 2014) with a Perc H710P controller in it. PowerEdge T130 + Perc H730 Original 4x 1TB 3. 7, SAS 6 Gbps, 300 GB, RPM 15k H710 PERC… Jan 24, 2022 · The Dell Perc H755 (installed on a R750) is now also tested with Debian Bullseye (Proxmox VE 7. Jun 12, 2021 · PERC H730 supported SAS Drives I want to replace current SAS hard Drives and I have been trying to find the hard drive specifacitons for a PERC H730 on a Power Edge R730 server. This explains the 32TB "Maximum internal storage" line on the other technical spec sheet I found (8 supported drives * 4TB each). Is it possible to use a Series 9 or 10 higher end card from that gen laying around like the H745 or 740P on an 11 or 12 Family server model? For reference: PowerEdge: List of PowerEdge RAID Controller types for Dell Sep 25, 2012 · The H710 DOES allow you to use 3rd party (non-Dell) branded drives, as long as the controllers firmware is current. I currently have 10 disks in a RAID10 array, and I need to expand the array, or create a new virtual disk with 2 new 1. What part number do I need to specify in the order? PAGE 65 Security Key And RAID Management 7 NOTE: PERC H310 does not support any security implementations. This RAID controller improves the performance of your server systems. PERC H710P: The PERC H710P is the same as the H710 with increased non-volatile flash write cache to 1GB. The PERC6 doesn't allow disk passthrough, so especially if you're using SSDs you may want to invest in a non-RAID card (e. 0 later, once the H710 has settled in. But When I go to PhysicalDisk Management, one of the hard disk is showing ‘Blocked’ That hard disk is also Dell Cheetah 15K. Right now I have a Dell T620 w/PERC H710 w/512mb cache. Keep in mind that disks over 2TB are not recognized as more than 2TB to the PERC 5/i and PERC 6/i. Manual says 12TB (6 x 2TB) but wondering if that can be pushed further? Like 6 x 4TB drives in RAID 10 or something like that. 5 Offers Non-RAID support for direct access to disk drives (PERC H310 only). 2. The H700 is supported in the R710 and does support disks larger than 2TB. Figure 1. Features such as CacheCadeTM provide accelerated performance over previous technologies. From my research, the perc H710 on my R720 can only do 6Gbps. Aug 22, 2018 · Did you ever find a solution to your problem? I'm currently in a similar situation. 5" HDD mentioned coming with the system. Other features on the front panel include an interactive LCD control panel, two USB connectors, a video connector and a vFlash media card slot. May 28, 2024 · Hello, About H710p it depends which sector used by hard drives, I beleive 512e drives for better compatibility. ce that drives 512 MB cache memory. An eight-port 6Gb/s PCI Express RAID controller, the Dell PowerEdge RAID Controller (PERC) H710P supports up to thirty-two 3Gb/s and 6Gb/s SATA or SAS hard-disk drives or solid-state drives. 6mm (6. Nov 14, 2018 · Originally my T7500 had 2xXeon E5620 / nVidia Quadro 4000 2GB / 48GB RAM / 500GB WD hard drive / Windows 10 Pro 64bit. HDD parameters: 600Gb, SAS, 3. NOTE: Mixing SAS and SATA drives within a virtual disk is not supported. In theory, the 12Gbps SAS drive should be able to “slow down” to 6Gbps and therefore be compatible with my server, right? I also am struggling to find a compatible drive list for the H710. 0 is the OS and 1 has all the live data. it has been fine up until I purchased several 3tb Seagate Constellation ES. 7 first and then upgrade to ESXi 7. Moreover Feb 26, 2013 · I put four WD2001FYYG (Western Digital 2TB SAS Enterprise Drives) in my brand new R720xd with a PERC H710 card. Mar 21, 2016 · The first firmware update added support for >2TB drives on the H700 controller. All of this is done on Connector 0. So, to answer your question, both are true: 2TB is the limit if using the PERC 6 (or SAS 6 or S-series controllers), and 3TB is supported on the H-series controllers. 0-capable expansion slots greatly increase your capacity, while optional hot-plug, front-access PCIe SSDs (up to four) enable performance-enhancing, in-box storage tiering. Aug 14, 2022 · I have a Dell Poweredge R620 with a Dell PERC H710P mini RAID Controller flashed into IT mode. If you are implementing hybrid server platforms based on solid-state storage, these next-generation PERCs exploit the potential of solid-state drives (SSDs) for unsurpassed performan Oct 29, 2021 · Check out our Dell PowerEdge PERC Raid Controller Comparison guide on our blog, covering compatibility, features, and cache to help you find the best fit. May 8, 2015 · The PERC H710 Firmware was updated and is the most current version, so looks like your problem could be the same one I had. Very. I see that there is a Connector 1. My query is mainly related to the PERC controller and disk performance. Under DOS or Linux some hard disk controllers may provide more or less information. 9 percent greater Yes, the h330, h730 and h730p support 4kn drives. PERC H330:The PERC H330 is a general purpose RAID solution card. x) and the perccli64 still works very well on both showing/setting parameters of the card and VDs. Updating firmware will NOT change this sector size incompatibility, in my experience. Sep 18, 2020 · 0 So you're thinking that because the new hard drives come from the same batch that you'll minimize your risk of having a completely failed array if the new drives have some weird failure or bug by using both old and new hard drives in each virtual disk? I'd posit that you'll create more risk by doing that. There are several types of PERC controllers available depending on internal or external storage connectors, maximum drive support, and RAID support. I don't really have any plans to use the PERC directly, since the box will be running unRAID, but Jan 19, 2017 · They will work without problems, stick to WD/Seagate Enterprise drives like R series and whatnot but Dell will not like it should you need to service, and only a problem if you NEED a tech service and are IN warranty. Currently Windows do detect the controller but list it as RAID controller and there is no driver available for cards before the HXXX series when I try to install it manually. So, if you are adding more than 5 HDDs, you should use RAID 5 or RAID 10 for the redundancy benefits. 03. Dec 27, 2013 · The Drivers and Downloads page for my T320 does not seem to include anything for the Perc H710 RAID controller I have. You'll then have two virtual drives Nov 21, 2015 · Hi, We currently have a PowerEdge R710 with 6 x 3. 3-0001) The vSphere 7 image and the Dell customized image does discover local storage on the PERC H710 Mini controller. The PERC 6 has a HARD limit of 2TB per physical disk. g. 1-0132. 2-0001 driver 5. NOTE: Mixing disks of different speeds (7,200 rpm, 10,000 rpm, or 15,000 rpm) and Figure 1 shows the front view of the 8-drive bay chassis with eight 2. (firmware version 21. I don't foresee an issue related to compatibility. The H710 is visible to the ESXi 7 installer. Sep 25, 2018 · With 512e sector emulation, the 710P will take up to 8TB drives. If you are experiencing any issues, you can manually download and reinstall. Upon purchase I asked them to install OS on an SSD (Kingston SA400S37/120G I found the technical spec sheet for it, and on page 29 it shows that the 3. The drives appear on the LSI 9266 compatibility list, but the Dell card blocks them, saying that they are incompatible. Aug 5, 2021 · Hello, I've installed a DELL PERC H710 Mini Mono RAID Controller - 512 MB Cache 5CT6D, and now I can see both SSD hard drives ! Thank you for your help Shine ! Meanwhile, I have another message during Boot process, linked to a PERC battery - should I order some additionnal part (battery)? Thank you,Thomas The T620 is available in several configuration options, supporting up to 12 3. I recently purchased a Poweredge T420 that came with a Perc H710. The PowerEdge R720xd allows you to quickly Max hard drive size (Dell R610 / PERC H700) Hi, Does any know what the maximum individual drive capacity is on a R610 with a H700 RAID card. The controller should support basically any drive that is SAS or SATA compatible. A Non-RAID hard drive is not fault-tolerant and cannot be recovered if it fails. A Dell PowerEdge RAID Controller, or Dell PERC, is a series of RAID, disk array controllers made by Dell for its PowerEdge server computers. You can deploy the PERC H710 in hard-drive-based server environment. Maybe the server has to be told to use SATA instead of SAS Jan 20, 2014 · Hello, On which level is this possible? Can I mix SATA and SAS disk on the RAID controller (PERC H710), group or virtual disk level? Server PowerEdge R720. 5" Enterprise Drive Dell - Seagate OEM Old consumer SSD - 2. The server has a PERC H710 in it and I figured it should be as simple as finding the drives Dell says to put in it "DELL KCVF5 4TB 7200RPM NEAR LINE SAS-12GBPS 512N 3. a SAS 6 (cheap, only supports less than 2TB and RAID0), or an H310 (a bit more, won't fit in the dedicated RAID slot so needs a PCIe slot, but does passthrough and supports RAID5)). When configured with the H710, the system idled silently. Jun 2, 2025 · Solution provided Eight-port internal SATA+SAS solution supporting up to 32 hard disk drives (HDDs) and solid-state drives (SSDs) Physical dimensions 167. Turn off the S110 in the system BIOS (F2) SATA Settings>Embedded SATA>AHCI Mode Integrated Devices>Integrated RAID Controller>Disabled Set the correct boot May 3, 2013 · Dell Technologies recommends applying this update during your next scheduled update cycle. If you were planning on using RAID 5, consider using RAID 6 instead. Dell PowerEdge RAID Controller (PERC) H310, H710, H710P, and H810 User’s Guide Regulatory Model: UCSA-801, UCSB-800, UCSM-800, ce that drives 512 MB cache memory. Aug 27, 2017 · I am trying to configure Raid on DELL PowerEdge R720. 5-0002) In terms of compatibility, 2TB was the big issue for many controllers. The Dell PowerEdge RAID Controller (PERC) H310, H710, H710P, and H810 User's Guide describes the features and specifications of these controllers. Also, mixing hard drives and SSDs within a virtual disk is not supported. On to the SSD’s… sponding hard drives 0, 1, 2, and 3. It has a RAID 1 with 2 hard disks and one of the disks in the failed state (the amber LED lights up) and the temperature indicator lights up, but this is the second question. You can try replacing PERC 6/i with PERC H700. 64 and a chassis with up to 8HD. Since the H730 controller is compatible with non-dell certified drives So the only real viable use for the Perc 5/i in 2025 is adding a few additional HDD hard drives to an older system. Can someone help me ? Dell PowerEdge RAID Controller 11 User’s Guide PERC H755, H750, H355, and H350 Controller Series Dell Technologies PowerEdge RAID Controller 11 Technical specifications of PERC 11 cards Technical specifications of PERC 11 cards The following table lists the specifications of PERC 11 cards: Table 1. H710 User's Guide Page 9: "Mixing SAS and SATA drives within a virtual disk is not supported. 5" front backplane connected to the internal PERC H700. I am looking to upgrade from 512MB RAM in my current PERC H710 to 2GB that the PERC H730P contains. The plan being to get the H710 installed and running under ESXi 6. If that is the case then you need to change the boot device to the H710 and create an array on the H710. Using the PERC H710P with CacheCade technology, which accelerates I/O performance of existing HDDs using SSDs as high-performance read cache, delivered 127. It wasn’t detecting my SAS drive before or after I flashed the controller, but I tested an SSD in the backplane and it worked… The PowerEdge RAID Controller (PERC) H730, with eight internal ports, delivers two PowerPC processor cores and a 72-bit DDR3 interface that drives 1GB non-volatile cache memory. Apparently the newer firmware has not been nerfed. Did MS remove the Perc 6/i drivers in the last release, where can I get those?? i tried the dell update packages but they changed nothing. You can deploy the PERC H710 in hard-drive-based server environments for significant performance gains. 5-in, 10K RPM Hybrid Hard Drive I am using RAID 5 for the above. 5 percent greater throughput and supported 2. All four hard drives show up as blocked in the H710 BIOS utility. Oct 30, 2017 · I have a Dell PowerEdge R720 with a PERC H710P Mini controller. Can you please tell me the compatibility of SSD drives with 2TB storage? Oct 11, 2015 · I have a R620 with PERC H710P Mini firmware 21. The 3 physical hard drives are configure with 2 virtual drives, 0 and 1. 5" Western Digital WD5000BPKT All seem to work ok I can only do RAID0 because I don't have multiple SSDs. 64 running for Dell PERC H310/H710/H710P/H810 Controllersfor the following Windows operating systems: Windows 2008 R2 64 Bit Dec 10, 2014 · The PERC 6 does not support disks larger than 2TB. Get the latest official Dell storage controller drivers for Windows 11, 10, 8. or flash the firmware to the IT version. In addition, the card connects to SATA and SAS hard disk drives, and solid state drives, allowing for tiered storage that optimizes cost and performance. This product has been tested and validated on Dell systems to ensure compatibility with your computer. I don't have any enterprise drives to try other than the 3. I plan on purchasing a new server. Looking to speed up system, and maximized capacity with SSD, perferably hardware encrypted (currently using bitlocker on original seagate ST9500620SS drives). 13. The only issue you will see is the drive will list itself as “Unsupported” in Open Manage, but will work and function as it should. 112. TechMikeNY is here to help. 00). I have tried cross-flashing to the LSI firmware, but I cannot get the The PowerEdge RAID Controller (PERC) H710, with eight internal ports, delivers two PowerPC processor cores and a 72-bit DDR3 interface that drives 512 MB cache memory. That being said, RAID 6 should be considered slow. 0 for PERC H740P, H840, H745P MX, H745 Adapter, H745 Front, H345 Adapter, H345 Front, H755 Front, H755N Mar 30, 2022 · I am thinking of buying a used R620, but I can't get good information about what drives are compatible. There is no technical guide that inform the maximum size drive that H710p could support. Oct 6, 2025 · This page provides tutorials about Hard Drives, Virtual Disks, and the RAID Controller (PERC) in PowerEdge Server. An eight-port 6Gb/s PCI Express RAID controller, the Dell PowerEdge RAID Controller (PERC) H310 ofers robust data protection, seamless migration, and the flexibility to use both SATA, SAS, and solid-state drives. Update drivers using the largest database. May 25, 2015 · You are correct in that the H710 would be better for what you are putting together, but keep in mind that Dell doesn’t support it because Dell’s firmware for the R610 probably isn’t as compatible with the H710 as it normally would be, so look for a hiccup here and there. NOTE: Operating systems can directly access Non-RAID hard drives. 121. Also, there are no lights on the drive caddies, so maybe they are not physically interfacing properly…? The drives seem to all fit securely, however. The PERC H730P, with eight internal ports, delivers two PowerPC processor cores and a 72-bit DDR3 interface that drives 2GB non-volatile cache memory. [1][2] The controllers support SAS and SATA hard disk drives (HDDs) and solid-state drives (SSDs). It explains how to replace a hard drive when it is failed or in predictive failure status. I would not, however, use desktop or NAS drives. Does the server still flash a warning light as others have reported? I’ve read the following post, but being ov… Aug 27, 2017 · I am trying to configure Raid on DELL PowerEdge R720. The PowerEdge RAID Controller (PERC) H710, with eight internal ports, delivers two PowerPC processor cores and a 72-bit DDR3 interf. 1) In the RAID controller, make sure you are using "Writeback" write caching policy, and not "Writethrough". The PERC6 does not "require" Dell drives though. A RAID controller is a hardware device on high-end servers or software program on low-end servers that are used to manage hard drives (HDDs) or solid state drives (SSDs) a server or storage Oct 27, 2020 · HDD compatibility with R720 and PERC H710 mini I need to by HDD for server PowerEdge R720 with raid controller PERC H710 mini. 5 times the number of users than the HDD-only configuration. PERC H810: The PERC H810 controller offers all the features of the H710P in addition to enterprise support for up to 192 hard drives in external enclosures like the PowerVault MD1200 and PowerVault MD1220 storage arrays. The PERC H740P RAID Controller from Dell offers reliability and performance in addition to providing management with the tolerant disk subsystem failures. Mar 6, 2012 · This package provides the driver version 5. 5INCH", and swapping them out. Sep 10, 2020 · Galling? Yes. If you are implementing hybrid server platforms based on solid-state storage, these next-generation PERCs exploit May 3, 2016 · I've run into a seemingly unsolvable problem trying to get my Dell PERC H710 to talk to 8TB SAS drives. It ensures that the system software remains current and compatible with other system modules (firmware, BIOS, drivers, and software) and may include other new features. Also, mixing hard drives and SSDs Jun 19, 2017 · One of them is Dell PowerEdge R620 (without LCD display) with PERC H710. Does anyone know if a firmware upgrade is in the works to have H710 & H810 raid controllers be compatible with 512e/4Kn block sizes? Currently only 13th Generation raid controllers support this. R710s came with either the old PERC6 which didn't discriminate drive firmware, or the H710 which did originally block non-Dell firmware. Oct 19, 2020 · This post will give some background on 4Kn sectored drives and some compatibility issues with Dell and HP RAID controllers that are not compatible with 4Kn hard drives. May 19, 2015 · How to expand a RAID array after adding new SATA hard drives to a Dell PowerEdge T320 on a PERC H710 Adapter Step 1: Install the new hard drive(s) in the available slots in the chassis Step 2: Launch the Dell OpenManage Server Administrator Step 3: Navigate to the Storage menu and expand the PERC H710 Adapter to locate the physical disks, which should show a Ready status (make note of the IDs Sep 13, 2016 · updated the firmware PERC H710 controller, drives and updated the firmware HD, when I entered the BIOS setup also demonstrates how locked. 5in) (MD2 low profile) Offers Non-RAID support for direct access to disk drives (PERC H310 only). The server is running ESXi and this is… Apr 14, 2015 · I recently purchased a Poweredge T630 server computer configured with a PERC H730 controller and two 1TB (raid 1) SATA drives. Oct 28, 2014 · Do third party drives work on Dell PERC Controllers? (specifically the H310, H710, H810, H330, H730, H830). Mar 13, 2024 · This release updates Windows 2019 Server driver to 7. Windows Server 2022 support by Dell servers Feb 15, 2022 · Read here to see the most common chassis compatibility questions we've received from customers about Dell PowerEdge servers. So is there a compatibility list for hard drives or components in general? Does it matter if I scratch together different brands/models as long as I stick to one size? EDIT: Perc6/i RAID Controller and 6 bay chassis UPDATE: I did some more research and found that the "EMC" was not just a random string in the part number. 2 SAS drives to expand the raid pool. I have a perc h310 mini and I put a couple of 4kn formatted drives in and the damn thing wouldn't even boot, The way I got around it was while it wouldn't boot it was because it would hang at initialising firmware interfaces but I could get into the rear controller before that. I have ProxMox installed on a 4TB physical hard drive that's set up as a one-disk RAID 0. As I am planning on using my machine as a NAS, I too purchased a Perc H310 and crossflashed the LSI 9211-8i P20 firmware. It is Sep 10, 2021 · I have inherited a server PowerEdge T420 server that’s 8 years old and due a replacement. 0. Aug 14, 2019 · I have a R620 with PERC H710P Mini firmware 21. 3. Supports Dell-qualified serial-attached SCSI (SAS) hard drives, SATA hard drives, and solid-state drives (SSDs). Upgrading the Dell PowerEdge R720 with a combination of hard drives and-solid state drives delivered a whopping 610. Compatible Hard Disk Controllers, RAID Controllers The following list contains the list of hard disk controllers tested and compatible with the Windows version of Hard Disk Sentinel. 5-inch hard drives. raf lxrlzd psiimgx mkdn pahl oymzqxs rgodzitc fgeyr ecp obnoa wiuci bhqv ynucmh nia sjkrz