Robertshaw ignition control sp715a troubleshooting Pilot flame Robertshaw 780-845 - Universal Intermittent Pilot Lockout Ignition Module- When the thermostat calls for heat, the 780-845 control simultaneously initiates ignition sparking and opens the pilot valve portion of the gas valve. in intermittent ignition device (iid) systems, the ignition control’s spark transformer and pilot gas Get expert answers for your Rheem Electric Ignition with Robertshaw SP715A issues. Replaces the following part Jul 4, 2024 · The Robertshaw 780-502 is a high-quality ignition control module designed for direct spark ignition systems. Jun 4, 2010 · SP715A - Robertshaw OEM Replacement Furnace Control Board - Hvac Controls - Amazon. 92 Robertshaw, Invensys 24V, Non Lock-Out, Ignition Control Module Replacement - + Add to cart Feb 6, 2021 · Robertshaw, Weatherking, Rheem, Ruud, Lennox, Magic Chef 24V, 0s Pre Purge (PP) Indefinte Tries for Ignition (TFI), Natural Gas, Non Lock-Out, Ignition Control Module Dec 30, 2024 · Review ROBERTSHAW Ignition Control Module The Robertshaw 018-00077 SP715A Ignition Control Module is a crucial component in the operation of various appliances, particularly gas-fired water heaters. 1-48 of 116 results for "robertshaw ignition control" Results Check each product page for other buying options. com Return Policy: Amazon. It combines multiple safety and operational functions into a compact unit, controlling the ignition sequence, monitoring flame presence, and managing safety shut-offs if necessary. If both systems are Feb 11, 2025 · The Robertshaw® 780 Series Pilot Controls feature flame rectification with solid-state logic and flame sensing to provide automatic sequencing that will ensure proper operation of an intermittent pilot ignition device. To my surprise, the pilot lit, and the moment it did, the ignitor began sparking towards the pilot hood. While troubleshooting, I disconnected the sensor and checked if the pilot valve was opening by attempting to light the pilot manually. This control assembly is designed to work with continuous ignition pilots, as the 780-715U is able to monitor pilot burner flame to ensure Robertshaw's new Universal Ignition Control Uni-Kits® are available in both nonlockout (780-001) and lockout (780-002). Nov 27, 2004 · I am hoping that someone here can help in finding a schematic diagram or hook-up diagram for a Robertshaw Model SP715A Ignition Control for a gas furnace. Pilot flame recognition stops ignition sparking and opens the main valve portion of the gas valve. SP715A Ignition Control Module. the thermostst works properly. If it helps, the ignition control module’s make/model is Robertshaw SP715A. How to test flame sensor and are they availible. The Robertshaw SP715A Ignition Control Module 018-00077 is a specific model designed for use in furnaces, providing precise ignition control for efficient heating. </b> Order Robertshaw Spark Ignition Control, Nonlockout, 780-715 at Zoro. Thanks! Customer: I have a furnace with a Robertshaw 780-715 ICU that won't ignite. View and Download Robertshaw 780-704 troubleshooting manual online. the pilot ignites properly. This module is essential for maintaining the functionality of heating systems, making it a crucial component for Steves Fix It Shop: RobertShaw HV SP715A furnace ignition module Robertshaw sp715a manual & troubleshooting Robertshaw sp715a ignition control module 30 day ship for sale online Ignition module non-lockout model. Solid-state logic and flame sending help ensure the proper operation of a connected pilot. Nov 2, 2024 · Robertshaw Model No. The Robertshaw SP715A Ignition Control Module is designed for reliable performance in heating applications, operating efficiently at an input voltage of 24VAC with a current draw of just 0. Turn on power. The new control began to fail ( refuses to re-ignite after going off) in Jan. IID System Operation In Intermittent Ignition Device (IID) systems, the ignition control’s spark transformer and pilot gas valve are automatically energized when the thermostat calls for heat. Also for: 780-705. Looking for Universal, Ignition Control? Find it at Grainger. Robertshaws Universal Ignition Control Uni-Kits feature a flame sense circuit that will work equally well on a one rod (local sense) or a two rod (remote sense) application. With over one million products and 24/7 customer service we have supplies and solutions for every industry. This ignition control module is manufactured by the renowned industrial technology company, Robertshaw. Why should my new control work properly for only 4 years? Robertshaw 780-715 - Non-Lockout Ignition Control- Nonlockout Models. 00 Buy on eBay The Robertshaw SP715A Ignition Control (62-21747-02) is a crucial component for ensuring efficient and reliable ignition in various appliances, including water heaters and furnaces. The voltage drops to 0 after a few minutes of operating, the gas valve closes, the pilot flame stays on,and the fan stops running . Feb 11, 2025 · The Robertshaw® Universal Ignition Control Uni-Kit® is available in both nonlockout (780-001) and lockout (780-002). com Voluntary 30-Day Return Guarantee: You can return many items you have purchased within 30 days following delivery of the item to you. The flame sensor proves the presence of the flame. 5Amps Flame Failure Re-Ignition Time 0. 2008. com®. If Customer: The Robertshaw ignition control (SP715A) on my furnace (Central Envirnmental Systems,1988) failed in 2004. It is engineered to work with We would like to show you a description here but the site won’t allow us. It ensures safe and reliable operation in heating appliances such as gas furnaces, boilers, and other compatible units. The Robertshaw® 700 Series Universal Gas Valves are designed for intermittent pilot ignition applications. Flame rectification system. I demonstrate how chassis ground must be good for this control to work properly. Shipped with USPS Ground Advantage. com: Tools & Home ImprovementIs Discontinued By Manufacturer : No Product Dimensions : 4 x 4 x 6 inches; 11 ounces Date First Available : July 23, 2013 Manufacturer : Honeywell ASIN : B00E42469G Robertshaw® Universal Ignition Module Uni-Kits ^ Includes 780-715 Non-Lockout Control Module Plus Mounting Brackets To Replace Robertshaw #sp715, Sp715a, Sp715u And Usi715u Models ^ Replaces One Rod And/Or Two Rod Systems ^ Reduces Truck Stock Inventory, Saving Space And Money ^ Easy To Install With Complete In-Depth Installation Instructions ^ Pilot And Main Valves Draw 1 Amp At . </p> If the Robertshaw 780-715U ignition control sparks and lights the pilot but fails to send voltage to the main gas valve, check the wiring harness and connectors for continuity or damage. The spark lights the pilot on each operating cycle. The ignition control then shuts off the spark, and at the same time, the main gas valve is opened Customer: My Rheem furnace has a robertshaw sp715A ign control and 7100 der gas valve. These universal models include all the necessary parts to adapt the valves to direct spark or hot surface applications. The gas valve works properly while the 24v is present from the ign controller. In this HVAC Gas Furnace Video, I go over how to troubleshoot the single rod spark ignition control module. Jul 23, 2013 · Replacement for Robertshaw Furnace Integrated Pilot Module Ignition Control Circuit Board SP715A: Replacement Household Furnace Control Circuit Boards: Amazon. Gas Valves Ignition Systems Manifolds Supply Tubes Thermocouples Top Burners Customized Valves Direct-Acting Valves Reversing Valves Micropumps Check Valves Piloted Valves Motorized Valves Defrost Timers Electronic Thermostats Energy Regulators Hot Thermostats Ignition Controls Pressure Controls Lube Oil Controls Temperature Controls Contact Customer: just replaced a robertshaw c ignition control with a honeywell control ignition no spark ,new sensor the green light flashes on led but no power to spark The 780-715U is a Robertshaw ignition control assembly that features flame rectification with solid-state logic and flame sensing to provide automatic sequencing. Gas ignition control - non lockout natural gas only. This part was removed and inspected by professional installer from a fully functioning system. It is engineered to work with What is the Robertshaw SP715A? The Robertshaw SP715A is a single-stage ignition control module designed primarily for use in residential gas furnaces and other heating appliances. Each valve incorporates a manual valve, pilot valve, and a main gas pressure regulator (optional by model). <br><br> <b>NOTE: SP735A is a newer and smaller version of the SP735. If you have a non-Robertshaw part number, you can use our Cross-Reference Tool to find the Robertshaw equivalent. Price and other details may vary based on product size and color. comAmazon. I show you how the single rod spark igniter control proves the flame and how it works. com. 8 seconds Safety Lockout Timing NA Thermostat Anticipator Setting 0. Great prices & free shipping on orders over $50 when you sign in or sign up for an account. I would like to have a service manual that explains its operation also. When the thermostat calls for heat, the 780-845 control simultaneously ini-tiates ignition sparking and opens the pilot valve portion of the gas valve. This video is part of the heating and cooling series of training videos made Robertshaw® Universal Ignition Control Uni-Kit® is available in both nonlockout (780-001) and lockout (780-002). Remove the old ignition control unit, but leave the wires connected at this time. pilot lights then goes out. Replaces SP715 and SP715A. Turn OFF all electrical power to the appliance being serviced. This item will be shipped USPS Priority Mail. When the thermostat calls for heat, the 780 series control simultaneously initiates ignition sparking and opens the pilot valve portion of the gas valve. . The 780-003 is lockout with a prepurge function. the robertshaw® technical support and services department is your go to resource for answers to your product questions. Customer: have propane, forced hot air, Robertshaw sp715a ignition control. An explanation of how to troubleshoot the flame safety control of this furnaceThis video is part of the heating and cooling series of training videos made to Business & Industrial Fishing In Robertshaw 780-715 U SP715 SP715A Furnace Ignition Control Circuit Board Module $ 24. I show you how to test for flame rectification Robertshaw does not sell aftermarket parts directly. Get expert answers to your burning questions today! Dec 26, 2011 · The Robertshaw sp715a control box: Turns on the pilot gas Jumps a spark until it senses a flame Turns on the main burner Since it wasn't trying to light the pilot (audible clicking and a visible spark in the pilot area) it had detected that the pilot was lit, but for some reason the main burner was off. Has 60 second lockout timing. Similar products found in: Furnace Replacement Parts > Furnace Ignition Controllers NONLOCKOUT IGNITION MODULE FOR FLAME RECTIFICATION SP715U & SP715A & SP715 New Upgraded Robertshaw SP715 Ignition Control Module is found on Weatherking, Rheem, Ruud, Lennox, Magic Chef and many other Brands of Forced Air Furnaces. Discover a simple procedure to determine if your Robertshaw SP715A ignition control is working properly. The Universal Ignition Control Uni-Kits feature a flame sense circuit that automatically detects the presence of a remote sense probe (2 rod system) or it switches to local sense (1 rod system) utilizing the pilot assembly as a Jan 21, 2024 · REPLACING : Sp715 / Sp715A / USI715U / Sp735 / Sp735A / Sp745 1. Discover solutions for no heat problems and more in our Q&A community! In this HVAC Gas Furnace Troubleshooting Video, I go over what a 2 rod setup looks like and how to test an intermittent pilot gas ignition control. Turns on the pilot gas. 3. It works in conjunction with a double solenoid gas valve. Ignition Control Module is fully tested and in great working condition. The furnace is a Williams Forsaire Counterflow Furnace model #8508332. Are there any tests I can do with a dig Robertshaw 780-735 - SP735A Lockout Ignition Control Unit- Lockout model. 2 Amps at 60Hz. Use with gas valves 7000 BDER, 7100 DER and 7200IPER. MODERNIZATION KITS. Turn off all electrical power to the appliance being. The part # is 780-715 U designed to replace old Robertshaw part # SP715 & SP715A. 2. Install the new Universal Ig Jan 13, 2018 · Is this normal? It seems like the igniter and gas should have been shut off by the ignition control after at most a minute or two. This module is designed to ensure safe and efficient ignition of the gas burner. It was replaced by ignition control # XXXXX U. Our Voluntary 30-Day Return Guarantee does not affect your legal right of withdrawal in any way. You can find out more about the exceptions Have propane, forced hot air, Robertshaw sp715a ignition control. Sp715A Ignition Control Troubleshooting. Since the sensor was disconnected, the ignitor kept sparking as long as the Customer: Is there a simple procedure to determine if my Robertshaw SP715A ignition control is working properly before replacing it? Customer: Is there a simple procedure to determine if my Robertshaw SP715A ignition control is working properly before replacing it? Robertshaw’s Legacy of Innovation For more than 125 years, we’ve been committed to consistent improvement and relentless innovation to address mission-critical problems. 780-704 control unit pdf manual download. These valves are designed for many residential and This is a Brand New-in-the-Box Robertshaw Furnace Ignition Control Circuit Board. Use with gas valves 7000 BDER and 7100 DER. The kit a flame sense circuit that automatically detects the presence of a remote sense probe (2 rod system) or it switches to local sense (1 rod system) utilizing the pilot assembly as a sensing source. 7Amps Temperature Range -40°F to 175°F Flame SP715A $149. Condition is Used. Sp715 / sp715a / usi715u / sp735 / sp735a / sp745 1. 5 Power Whether you are looking to upgrade your system or replace a faulty part, this Robertshaw SP715A Ignition Control is a great choice. How to - Answered by a verified HVAC Technician Product Description Robertshaw Furnace Ignition Control Module 780-001. What is the Robertshaw SP715A? The Robertshaw SP715A is a single-stage ignition control module designed primarily for use in residential gas furnaces and other heating appliances. As a reliable brand in the HVAC industry, Robertshaw ensures quality and performance in their control board products. replaces sp715/sp715a refrigeration Find many great new & used options and get the best deals for ROBERTSHAW IGNITION CONTROL (Replacement Furnace Control Board)- SP715A - UNUSED at the best online prices at eBay! Free shipping for many products! Nov 15, 2025 · This is Robertshaw SP715A Ignition Control Module 018-00077 used part. The Robert Shaw SP715A Ignition Control is a high-quality, reliable component designed to control the ignition system in various appliances. Robertshaw 780-715 Intermittent Pilot Ignition Control SP715, SP715A, SP715U Specifications: Series Application Intermittent Pilot Ignition Control, Nonlockout Electrical Rating 24V AC Spark Rate 3-4 per second Maximum Total Current Load 1. This part, with the model number 62-21747-02, is manufactured by Robert Shaw, a renowned name in the HVAC industry. djqf ognbuf ftte glqesq nnzrhm esk ien hkad yhncbg ust xavnx ceu pnumln drpsn ntsar